SN-WC Series
Walkway Fixing Clamps (C / L / M Type)
Bolted clamps that fix walkway grating to roof seams, purlins or rails.
View specifications
PROJECT-FOCUSED PRODUCT SUPPLY
Secure connections, down to the detail.
Find mid, end, universal and laminate clamps for module retention. Match frame height, approved clamping zones, bolt engagement and tightening torque to the module and mounting instructions.
SN-WC Series
Bolted clamps that fix walkway grating to roof seams, purlins or rails.
View specificationsSN-CEND
Matched module retention with clear assembly and compatibility requirements.
View specificationsSN-CLAM
Matched module retention with clear assembly and compatibility requirements.
View specificationsSN-CMID
Matched module retention with clear assembly and compatibility requirements.
View specificationsSN-CUNI
Matched module retention with clear assembly and compatibility requirements.
View specificationsValues marked "sample" are indicative. Verify the selected model and project design before ordering.
| Product / Model | Material | Module Frame Height | Fastener | Torque |
|---|---|---|---|---|
| Walkway Fixing Clamps (C / L / M Type)SN-WC Series | Formed steel with zinc-plated bolt (confirm finish per drawing) | N/A — for walkway grating 15–50 mm | Threaded bolt with nut and washer | Confirmed on the order drawing |
| Aluminum End ClampSN-CEND | AL6005-T5 | 30 / 35 / 40 mm, select matching height | SUS304 M8 | 14–16 N·m for M8; laminate clamps require module-specific approval |
| Frameless (Laminate) Module Clamp with EPDM PadsSN-CLAM | AL6005-T5 with EPDM pads | Frameless laminate, typically 6–8 mm; verify module approval | SUS304 M8 | 14–16 N·m for M8; laminate clamps require module-specific approval |
| Aluminum Mid ClampSN-CMID | AL6005-T5 | 30–40 mm framed modules | SUS304 M8 | 14–16 N·m for M8; laminate clamps require module-specific approval |
| Universal Mid/End ClampSN-CUNI | AL6005-T5 | Adjustable 30–46 mm frames | SUS304 M8 | 14–16 N·m for M8; laminate clamps require module-specific approval |
Mid clamps retain neighboring modules; end clamps retain a module at the array edge. Select each against the module frame and rail interface.
No. Also verify frame shape, clamping zone, rail slot, bolt engagement and module installation instructions.
Do not substitute them. Frameless modules need a compatible laminate clamp and module-specific installation approval.
Use the confirmed instructions for the exact clamp, bolt and module combination. A catalog torque should not override the approved assembly instructions.
No. Check the listed adjustment range and the actual frame and rail geometry before selecting a universal clamp.
Contact us; commercial terms are confirmed in the written quotation.
LET’S BUILD WHAT’S NEXT
Share your layout, specifications and delivery requirements. Let’s build a coordinated supply plan.