SN-GS Series helical piles connect PV racking to ground foundations selected after a geotechnical review. SolarNova is a supplier/exporter; listed figures are indicative.

  • Catalog examples include 76 × 1600 mm shafts
  • Standard, dual-helix, four-helix and continuous-spiral types
  • Flange, U-bracket and no-flange connections as drawn
  • Site investigation and pull-out tests required for selection
Discuss SN-GS Series on WhatsApp ↗

TECHNICAL OVERVIEW

Product specifications

Technical specifications
Installation SiteFill, clay/cohesive, silt, sandy and sandy-gravel soils after geotechnical review
MaterialTypically Q235B-grade carbon steel or equivalent, hot-dip galvanized
Foundation/FixingHelical shaft with flange connection; dimensions and connection drawing confirmed per structure
Catalog examples (factory drawings)76 × 1600 mm examples: SN-GS-F76x1600, SN-AS-F76x1600, SN-AS-N76x1600, SN-GS-U76x1600, SN-DS-F76x1600, SN-FS-F76x1600, SN-WS-F76x1600. Other sizes confirmed per project in the written quotation.
Shaft DiametersTypical diameters include about 76, 89, 102 and 114 mm. Final specs confirmed per project in written quotation.
Wall ThicknessTypically about 3–3.5 mm. Final specs confirmed per project in written quotation.
Pile LengthTypically about 1000–3000 mm. Final specs confirmed per project in written quotation.
Flange DiameterTypically about 200–220 mm. Final specs confirmed per project in written quotation.
Surface FinishTypically hot-dip galvanized, with zinc coating typically over 80 μm. Final specs confirmed per project in written quotation.
Pile TypesStandard helix, dual-helix, four-helix, extended length and adjustable piles; custom sizes after review
Pull-out / Load CapacitySite investigation required; on-site pull-out tests recommended. Capacity confirmed per project in the written quotation. Final specs confirmed per project in written quotation.
Soil LimitationsGenerally not selected for hard rock or dense gravel without special measures; soft rock may need pre-excavation
Design Reference StandardsDesigned with reference to applicable regional wind and snow design codes; project-specific verification required
Warranty10-year product warranty, 25-year design service life.

Specification table

Helical pile examples from the factory catalog (prefix mapped to SN-). Dimensions as marked 76 × 1600 mm. Final specs confirmed per project in written quotation.
ModelForm shown in the catalog
SN-GS-F76x1600Helical shaft with base flange
SN-AS-F76x1600Helical shaft with flange and adjustment hardware
SN-AS-N76x1600Helical shaft, no flange, hole at the base
SN-GS-U76x1600Helical shaft with U-bracket base
SN-DS-F76x1600Dual-plate helix with base flange
SN-FS-F76x1600Multi-turn helix with base flange
SN-WS-F76x1600Continuous spiral with top flange

Product overview

SolarNova is a supplier/exporter of helical ground screw piles for PV foundations. The factory catalog shows 76 × 1600 mm examples across standard helix, dual-helix, multi-helix and continuous-spiral forms, with flange, U-bracket or no-flange connections (SN-GS, SN-AS, SN-DS, SN-FS and SN-WS types). Listed dimensions are indicative; custom sizes need a project review rather than selection from a universal capacity table.

Fill, cohesive clay, silt, sandy and sandy-gravel soils may be considered after site investigation. Hard rock and dense gravel generally need special measures, and soft rock may require pre-excavation. We recommend on-site pull-out tests to verify the foundation design before releasing a project order.

Applications

  • Fill, clay/cohesive, silt, sandy and sandy-gravel soils after geotechnical review
  • EPC and installer procurement

Related products

Frequently asked questions

Can pile capacity be selected from shaft size alone?

No. Soil conditions, helix geometry, installation depth and structural loads all matter. Require site investigation and use pull-out tests to verify the proposed foundation.

What materials are specified?

Typically Q235B-grade carbon steel or equivalent, hot-dip galvanized

What information is needed for a proposal?

Send the module drawings, site survey, local design loads and corrosion conditions. Listed figures are indicative; final specs confirmed per project in written quotation.

How are quantity, lead time and packing agreed?

Project quantity; sample availability and MOQ confirmed on inquiry. Typical lead time: 15–20 days after order and drawing confirmation; samples and standard parts faster. Export cartons or protected pallets; loading plan confirmed with quotation.

What warranty applies?

10-year product warranty, 25-year design service life.

What are the payment terms?

Contact us; commercial terms are confirmed in the written quotation.